Heating, HVAC and heat sources

Function blocks in the group “Heating, HVAC and heat sources”. Each link opens the block page; sorted by library and name.

Block Page title Library What it is for
t14_bit_rotation Bit rotation HVAC Bit rotation shifts and rotates bits in a vector, based on rising or falling edges on the inputs.
t1_equithermalcurve Heating curve HVAC A heating curve calculates heating water setpoint based on the outside temperature: the lower the outside temperature, the higher the heating water setpoint.
t28_dew_point Dew point calculation HVAC The function calculates dew point temperature of humid air at standard pressure of 101 325 Pa, based on air temperature and relative humidity.
t29_enthalpy Enthalpy HVAC The function calculates enthalpy, or energy of humid air, partial water vapour pressure, and absolute humidity from air pressure, temperature and humidity.
t2_three_point_control Three-point control HVAC The block converts a 0…100 % signal to opening and closing pulses to control a three-point peripherial, such as a valve or damper actuator.
t32_operating_hours Operating hours counter HVAC The block measures total activity time of a binary input, or cumulated operating time of the connected aggregate (pump, fan, boiler).
t33_min_max_controller Minimum and maximum controller HVAC The block monitors the measured value and announces exceeding of alarm limits.
t34_e_max Load shedding (E-Max) HVAC The block controls (shuts off) up to 8 groups of aggregates to keep the energy consumed in a 15 minutes interval below a given limit.
t35_pump_switch Pump switch HVAC The block switches pumps or other aggregates on a periodical basis, and automatic changeover if one pump fails.
t36_power_meter Power meter HVAC The block calculates instantaneous power (or any other value, like flow etc.) from a cumulated value which is brought to the input (energy, water volume).
t37_average_power_meter Average power meter HVAC Calculation of derivation of input signal.
t39_recuperation Heat / Cool recovery HVAC The block is a decision and control element for heat (or cool) recovery strategy at an air handling unit with mixing dampers or heat recovery plate / wheel.
t40_solarcalculator Solar calculator - Astronomical clock HVAC The function calculates the position of the Sun for given geographical coordinates and time.
t6_three_point_control_feedback Three-point control with feedback HVAC The block converts a 0…100 % signal to opening and closing pulses to control a three-point peripherial, such as a valve or damper actuator.
t8_three_point_controller Three-point P controller HVAC The block is a P-controller with a three-point output.
CascadeController Cascade Controller (v1.2) Lib.Mervis Libraries Block used for controlling devices connected in a cascade, it is an extension of the previous version.
CascadeControllerSwitcher Cascade Controller Switcher (v1.1) Lib.Mervis Libraries Auxiliary block used to enable the use of a combination of one modulated source and several non-regulatable sources with a cascade controller.
EquithermalCurve Equithermal Curve (v1.0) Lib.Mervis Libraries Block for calculating the heating medium temperature according to the equithermal curve.
EquithermalCurve4Point Equithermal Curve - Using Four Points Lib.Mervis Libraries A block for calculating the heating medium temperature according to an equithermal curve defined by four points.
ModulatedBoiler Modulated Boiler (v1.5) Lib.Mervis Libraries Block used for controlling the performance of a boiler with a modulated burner and a circulation pump.
ModulatedSource Modulated Source (v2.0) Lib.Mervis Libraries Block used for controlling the performance of a source (primarily a boiler with a modulated burner and a circulation pump).
ModulatedStage Modulated Stage (v1.0) Lib.Mervis Libraries Block used for controlling the performance of a general modulated source.
OneStageBoiler One-stage Boiler (v1.1) Lib.Mervis Libraries Block used for controlling the performance of a boiler with a single-stage burner and a circulation pump.
OutsideTemperature Outside Temperature (v1.2) Lib.Mervis Libraries Block used for processing outside temperature, calculating average daily temperatures, and blocking heating.
ReturnTempController Return Temperature Controller for Boiler Blocks (v2.0) Lib.Mervis Libraries Auxiliary block for boilers used for controlling the return water temperature.
TwinPump Twin Pump Control (v1.4) Lib.Mervis Libraries A block used for controlling twin pumps.
TwoStageBoiler Two-stage Boiler (v1.4) Lib.Mervis Libraries Block used for controlling the performance of a boiler with a two-stage burner and a circulation pump.
TwoStageBoilerWithReturnTemp Two-stage Boiler with Return Temperature Controller (v1.3) Lib.Mervis Libraries Block used for controlling the performance of a boiler with a two-stage burner and a circulation pump, where monitoring of the boiler return temperature is necessary.
TwoStageSource Two-stage Source (v2.0) Lib.Mervis Libraries Block used for controlling the performance of a source (primarily a boiler with a modulated burner and a circulation pump).