Download

30.6.2025

  • ST Text Editor – Added support for toggling text overwrite mode via the INSERT key
  • ST Text Editor - Fixed crash when adding a breakpoint in ST code with multiple new controllers, one lacking an assigned program
  • Property Grid – Fixed the Reset [R] button to correctly unset assigned DataPoint Template and Schema
  • Watch – Resolved a bug that caused an exception when more than one item was deleted
  • RT – Fixed the launch of communication functions – now synchronized with the computation cycle
  • Modbus Server – Fixed error reporting for overlapping registers

23.6.2025

  • HMI Graphic Editor, Template gadget, template selection – fixed sorting of available templates
  • Reading consumption profiles from MBUS electricity meters EMU Professional II LP
  • Added native function to allow saving a variable to history from ST code
  • Minor adjustments to the ST code hinting tool for block expressions (VAR, NAMESPACE, …)
  • Fixed reading of value in Modbus server
  • Fixed indication of manual mode for a variable
  • Fixed display of non-existent variable in mapping editor
  • Fixed expansion of variables in variable browser
  • Fixed IDE freeze when attempting to stop PLC during active debugging mode
  • Fixed RT update on Wago PLC when upgrading from version 2.5
  • Expanded library compatibility checks
  • Fixed crash when attempting to send email
  • Fixed linear conversion in Modbus CSV import
  • Fixed variable selection in SSCP client channel
  • Extended capability to read duplicate DIF/VIF in MBUS client channel
  • Fixed termination of connection in CloudAccess client
  • Added functions for time conversion between Unix32 epoch time and data type DT

16.6.2025

  • Fixed an issue that caused a .NET exception in the Output window: Could not load file or assembly 'System.Text.Encoding.CodePages'
  • SCADA Export – fixed the 'DateTimeKind' setting for exported data points ('UTC for PLC RTC', 'Local for other variables)
  • Variable Browser, Excel Import – fixed import of empty cells (previous behavior skipped setting the property value, now it is set to 'null')

9.6.2025

  • Added validation to prevent leading and trailing whitespace characters in username and password textboxes
  • SCADA Export - Resolved an issue where the +/-/INIT action property buttons did not adhere to the defined min-max value range
  • Port Monitor - Fixed a bug where changes in the Controller selector unintentionally modified the selection in the Debug controller selector
  • History Profile Dialog - The label “Min. Save Period” has been renamed to the more descriptive “Debounce Interval” with a tooltip “Prevents saving data too frequently”

24.4.2025

  • Dialog Open Solution – Fixed a crash occurring when selecting “Open in current instance” and then pressing the Cancel button
  • Fixed the duration of the splash screen display at application startup
  • SCADA DP Table Editor – Fixed a crash occurring when creating two or more groups with the same name at the same level and then importing data points

10.4.2025

  • Property Grid – Fixed behavior of the input/output editor
  • FBD Editor – Added existing variable; unified behavior when invoked from the context menu and keyboard shortcut Ctrl+Shift+E
  • Optimization – Improved loading and building of projects
  • Resizable Dialogs – Added the ability to resize selected dialog windows
  • Multi-Monitor Setup – Adjusted behavior for setups with different DPI settings
  • IDE Crash Fixes – Resolved crashes triggered by Ctrl+F in the ST editor
  • Solution Explorer Stability – Fixed crashes occurring when clicking inside Solution Explorer immediately after project build
  • Modbus Server Editor – Added export/import for the Note field
  • Breakpoints in ST Editor – Fixed behavior issues
  • Function Block Naming Issue – Fixed exceptions occurring when trying to open renamed copied function blocks in Solution Explorer
  • History Log Stability – Resolved crash when deleting the History Log
  • HMI Enhancements – Added support for the ST Subrange data type
  • Watch Variables Fixes – Adjusted behavior for structured-type variables
  • FBD Editor Stability – Fixed crash when using Remove Definition for multiple selected variables
  • Watch Enhancements – Retaining previously added variables after project reopening
  • Note Resizing in FBD Editor – Fixed issue preventing resizing of notes
  • SCADA DP Table Editor – Added an option to create a data point indicating loss of communication with the PLC
  • Graphic Template Editor – Fixed an issue where Chart gadgets copied from WebPanel Template to Scada Template caused variable disconnection
  • Language Translations – Corrected some translations
  • Watch Enhancements – Enabled adding variables from Server Editor (e.g., Modbus Server)
  • SoftPLC Link Improvements – Allowed manual entry of the name, type, and GUID of a communicated data point
  • Data Source Enhancements – Added an option to define a relative path to *.exs files
  • Debugging Improvements – Displayed Configuration Properties even during debugging
  • Variable Browser Enhancements – Added columns with Actual Value to .xlsx exports
  • New Prototypes Added – Supplemented new prototypes for Extension xS52, xS53, and xS54
  • Fixed duplication of attributes in communication groups
  • RT: Fixed closing of TCP communication channels, preventing their exhaustion and communication failure
  • Fixed frame numbering, change detection, and memory issues in the IEC60870 protocol; added a library of supporting function blocks
  • Fixed error reporting for non-existent mapped variables in server channels
  • Adjusted simultaneous display of communication errors and manual mode
  • Fixed default settings for link communication parameters
  • Project type change is now only possible one-way (from executable to library)
  • Modified error reporting during RT updates
  • Updated configuration for Unipi Technology modules
  • Fixed factory reset configuration for Unipi Technology PLCs
  • Optimized web panel file uploads
  • Increased allocated memory size for variable backup to FLASH
  • Extended port monitor outputs for Amit protocol
  • Added font size adjustment in the text editor using Ctrl + mouse wheel
  • Fixed quick response detection in the IEC 62056-21 protocol
  • Fixed serial port usage in I/O functions from ST
  • Fixed alarm list generation for PLCs
  • Fixed RFC2217 driver hang-up
  • Fixed NextOutput behavior in the T19 Int Scheduler block when transitioning from Sunday to Monday
  • Resolved TCP communication freezing due to network issues
  • Fixed long wait times during ST code debugging
  • Corrected timeout settings for TCP and UDP communications
  • Added Cloud Access connection type for PLCs in IDE
  • Fixed SunShine output in the T40 Solar Calculator block
  • Modified autogen behavior for variable generation and mapping
  • Added highlighted word selection in the ST editor
  • Fixed Cloud Access client configuration generation on PLCs
  • Enabled subrange data types in historical profile definitions
  • Added the atan2 function