====== RcWare Vision ====== ===== Current Installers (Hotfixes) ===== Select the installer matching your OS and .NET requirements. **English Versions** * **Hotfix for .NET 1.1** (Recommended for Win 10/11) * Version: **30.10.2025** — [[https://drive.google.com/drive/folders/1viznbQfUwkmJGI9AZ8%5Fb7rW0g722xtbB|Download (hot_fix_net11_eng.exe)]] * **Hotfix for .NET 4** * Version: **27.10.2025** — [[https://drive.google.com/drive/folders/1viznbQfUwkmJGI9AZ8%5Fb7rW0g722xtbB|Download (hot_fix_net4_eng.exe)]] **Czech Versions** * **Hotfix pro .NET 1.1** * Version: **30.10.2025** — [[https://drive.google.com/drive/folders/1viznbQfUwkmJGI9AZ8%5Fb7rW0g722xtbB|Download (hot_fix_net11.exe)]] * **Hotfix pro .NET 4** * Version: **27.10.2025** — [[https://drive.google.com/drive/folders/1viznbQfUwkmJGI9AZ8%5Fb7rW0g722xtbB|Download (hot_fix_net4.exe)]] > **Upgrade Note:** When moving from **.NET 1.1** to **.NET 4**, you must uninstall **RcWareExtensions** and delete the `rcware.exe.config` file from the application directory first. ===== Extensions & Utilities ===== **Basic Extensions** * **Standard:** v3.3.2016 [1.4.104] (`RCWareExtensionsSetup.msi`) * **.NET 4:** v3.3.2016 [4.1.12] (`RCWareExtensionsSetup.msi`) **OPC Server** * **Version:** 19.3.2008 (`ESG.OPCServer.RcWareSetup.msi`, `RCWareOPCServerExtensionSetup.msi`) * **Requirement:** Requires **OPC Core Components 3.00**. **Web Interfaces (RcWeb & RcWebGate)** * **Standard:** `rcwebSetup.msi` (EN/CZ), `WebGateSetup.msi` * **.NET 4:** `rcweb_en.zip`, `WebGateSetupNet4.msi` **Utilities** * **SQL Extensions:** SQL integration tools. * **SCADA Converter:** `Scada2ConverterFromRc.zip` (Found in `\Utilities` folder). ===== Critical Installation Warnings ===== **1. Avoid Program Files** * **Issue:** Windows UAC prevents RcWare from running correctly in protected folders. * **Solution:** Install to a root directory (e.g., `C:\RcWare\`). **DO NOT** use `C:\Program Files\`. **2. Windows 11 & Windows 10 (Update KB5011048)** * **Issue:** .NET 4 version crashes on startup or communication. * **Solution:** Use the **.NET 1.1** version. [[https://drive.google.com/drive/folders/1RZPOzmkceC4S5uC9eVwKx7ki5B7gBVUm|Download .NET 1.1 Repository]]. * **Note:** Uninstall `RcWare Extensions 4.0.17` before switching to .NET 1.1. * **Troubleshooting:** If .NET 1.1 won't install, see this [[https://techjourney.net/install-microsoft-net-framework-1-1-on-windows-10-8-7-vista-fix-regsvcs-exe-error/|RegSvcs.exe fix]]. ===== Quick Help ===== **UI Controls / Buttons Out of View** To fix font scaling issues, update these Registry entries via **Regedit.exe**: ''[HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Fonts]'' | Entry | Value | | --- | --- | | "Courier 10,12,15" | "COURE.FON" | | "MS Sans Serif 8,10,12,14,18,24" | "SSERIFE.FON" | | "MS Serif 8,10,12,14,18,24" | "SERIFE.FON" | **Incorrect Text Characters (Non-English)** * Download/install this font: {{ :en:rcware:sserifee.zip |}} * Ensure "Language for non-Unicode programs" is set to your local language in **Control Panel > Region > Administrative**. {{:en:rcware:windows_11_language_settings.png?400|}} ===== Version History ===== Below is the chronological list of updates. **Note:** Recent updates focus primarily on **SCADA Converter** tools for migration to Mervis SCADA. ===== 2025 ===== * **2025/10/30 - HOTFIX**: SCADA Converter: Fix for non-standard buttons in schemas. * **2025/10/27 - HOTFIX**: SCADA Import: Button transfer for String/TimeSpan; SCADA Export: Text support in port mapping (e.g., “/dev/tty00”). * **2025/10/01 - HOTFIX**: Schema Animation: Script length increased to 12,800 chars. * **2025/08/20 - HOTFIX**: SCADA Converter: Added write value setting to “Button”. * **2025/08/06 - HOTFIX**: Schemas: Added write value to “Button” and format string to “Value Display” (SCADA only). * **2025/07/30**: SCADA 2 Import: Added decimal place transfer. * **2025/07/01 - HOTFIX**: SCADA Export: Format string setting for TimeSpan data points. * **2025/05/30 - HOTFIX**: SCADA Export: Fixed station reference conversion in schemas. * **2025/04/25 - HOTFIX**: SCADA Import: Fix for group and tech unit assignment. * **2025/04/14 - HOTFIX**: SoftPLC Link: Added string replacement in variable names (bulk). * **2025/04/01 - HOTFIX**: SSCP: Additional parameters for bulk functions. * **2025/02/19 - HOTFIX**: SCADA Converter: Added communication period setting. * **2025/02/05 - HOTFIX**: AMiT Export: TPG definition for time programs only. * **2025/02/04 - HOTFIX**: SCADA Converter: Support for multiple AMiT PLCs. * **2025/01/30 - HOTFIX**: AMiT Export: XML character fix; SCADA Converter: Default AMiT timeout set to 15s. ===== 2024 ===== * **2024/12/13 - HOTFIX**: AMiT: Bulk row/column shift in matrix. * **2024/11/12 - HOTFIX**: SCADA Converter: Modbus telegram pause; AMiT digital point value type fix. * **2024/07/10 - HOTFIX**: SCADA Converter: Fix for RT2 AlarmPoint masks. * **2024/05/28 - HOTFIX**: SCADA Export: “Create configuration files only” option; New OPC UA Item Reader version. * **2024/03/25 - HOTFIX**: SCADA Export: CloudAccess channel fix; OPC Import: GUID change export; New OPC UA tree loading utility. * **2024/03/05 - HOTFIX**: SCADA Converter V5; Fix for station detection in exports. ===== 2023 ===== * **2023/10/10 - HOTFIX**: SCADA Export/Converter: Added history type preference order. * **2023/08/18 - HOTFIX**: AMiT: DB.txt variable selection and saving fix. * **2023/06/28 - HOTFIX**: SCADA Import: Group name and digital mask state loading fixes. * **2023/06/08 - HOTFIX**: SCADA Import: Analog button support. * **2023/05/25 - HOTFIX**: SCADA Export: “Show empty groups” default set to true. * **2023/04/12 - HOTFIX**: SSCP: SSL parameter added; SCADA Converter: Schema background image fix. * **2023/03/25 - HOTFIX**: SSCP Import: AMiT matrix to SSCP variable conversion fix. * **2023/03/23 - HOTFIX**: SoftPLC Import: TPG flag creation; SCADA Converter: Schema/Graph upload fix. * **2023/03/17 - HOTFIX**: OPC Import: SEL type naming/output fix; SSCP Import: AMiT and Sauter PLC support. * **2023/03/08 - HOTFIX**: SCADA Converter: SoftPLC/SSCP animation fix; SCADA Export: Option to disable save triggers for DB/HW groups. * **2023/02/13 - HOTFIX**: SCADA Converter V4: Individual DB saving settings for groups. * **2023/01/03 - HOTFIX**: SCADA Converter: MervisDB communication fix for all drivers. ===== 2022 ===== * **2022/11/28**: GIF conversion fix for SCADA. * **2022/11/21 - HOTFIX**: SCADA Converter: TimeStamp history settings; Bulk functions: >6 buttons per point support. * **2022/10/11 - HOTFIX**: SCADA Converter: projects.config rights and channel description expansion; Bulk functions: Independent button value type setting. * **2022/08/15 - HOTFIX**: Bulk driver change: Preserve memory location fix. * **2022/08/10 - HOTFIX**: SCADA Converter: SET button fix for “Controller Time”. * **2022/08/09 - HOTFIX**: Modbus TCP: “Align type conversion with SCADA” setting. * **2022/07/29 - HOTFIX**: Graph Templates: Fix for “Show state duration” visibility. * **2022/07/26**: SCADA Export: OPC settings disabled in DEMO mode. * **2022/07/12 - HOTFIX**: Bulk functions: Button type change; SCADA Export: DS channel support for SoftPLC. * **2022/06/28 - HOTFIX**: SCADA Converter: Multi-line text formatting fix for schemas. * **2022/06/20 - HOTFIX**: RcWeb: Schema “non-update indication” fix. * **2022/05/30 - HOTFIX**: SCADA Conversion: Graph template name saving fix. * **2022/05/27 - HOTFIX**: SCADA Import: StringInput adjustments. * **2022/05/03 - HOTFIX**: DH Import: GUID usage fix. * **2022/04/11 - HOTFIX**: DH Import: CSV enum mask fix. * **2022/03/25 - HOTFIX**: SCADA Converter V3: Custom path setting. * **2022/03/18**: Schema objects min size set to 2px. * **2022/03/18 - HOTFIX**: SCADA Converter: Schema animation fix; DH Import: CSV variable loading fix. * **2022/02/28**: SSCP: AlarmPoint type assignment fix. * **2022/02/21 - HOTFIX**: Import: Digital interface alarm fix. ===== 2021 ===== * **2021/12/15 - HOTFIX**: SCADA Conversion: MervisDB driver parameters; SCADA Converter: OPC UA channel fix. * **2021/11/25 - HOTFIX**: Schemas: 2px minimum object size. * **2021/11/05 - HOTFIX**: SCADA Converter: UDP timeout adjustment; Renumbering: Tech unit/group now starts from x.y.0. * **2021/10/14 - HOTFIX**: SCADA Converter: TPG color table export fix. * **2021/09/06 - HOTFIX**: DH Import: Added coefficient. * **2021/09/01 - HOTFIX**: SCADA Converter: TPG color table export. * **2021/08/18 - HOTFIX**: SCADA Converter: DB special character fix. * **2021/07/27 - HOTFIX**: SCADA Converter: Separate station export fix. * **2021/07/21 - HOTFIX**: SCADA Converter: TCP timeout adjustment. * **2021/07/19 - HOTFIX**: SCADA Converter: SSCP timeout adjustment. * **2021/06/25 - HOTFIX**: SCADA Converter: MervisDB parameters fix. * **2021/06/21 - HOTFIX**: SCADA Import: String button and Unit loading support. * **2021/06/08 - HOTFIX**: SCADA Import: Automatic DP evaluation; digital mask loading. * **2021/04/23 - HOTFIX**: SSCP: TPG Bool export fix. * **2021/03/31 - HOTFIX**: SCADA Conversion: Graph legend length transfer. * **2021/02/25 - HOTFIX**: Multi-threaded script syntax check; New SCADA Converter version. * **2021/01/13**: SCADA Export: ResourceAccessPolicy for schemas. ===== 2020 ===== * **2020/12/09 - HOTFIX**: SCADA Converter update. * **2020/11/23 - HOTFIX**: SCADA Export: RT2 AlarmPoint adjustments. * **2020/11/13 - HOTFIX**: SSCP Import: AlarmPoint support; SCADA Export: Per-channel TCP parameters. * **2020/11/03**: Modbus TCP: Reading group optimization; Endianness/Data type expansion (Double, Int64). * **2020/10/30 - HOTFIX**: Import: dpGuid column support. * **2020/10/22 - HOTFIX**: SCADA Converter update. * **2020/10/09 - HOTFIX**: Driver: TPG import expansion. * **2020/09/10 - HOTFIX**: Bulk DP renaming; SSCP dialog fix. * **2020/09/04 - HOTFIX**: SCADA Export: Empty text parameter fix. * **2020/08/18 - HOTFIX**: SCADA Export dialog adjustments. * **2020/06/19 - HOTFIX**: Modbus import adjustments. * **2020/06/17 - HOTFIX**: Modbus TCP: Timeout/Pause column fix; Import: Name separator fix. * **2020/06/11 - HOTFIX**: Modbus Import: Analog buttons and conversion. * **2020/06/09 - HOTFIX**: Modbus DP import. * **2020/04/21 - HOTFIX**: SCADA Conversion: Project domain setting; Bulk renaming: 'at the end' option. * **2020/04/14 - HOTFIX**: Schemas: Text comparison (A.X == “Abc”); SCADA Export: Modbus endianness fix. * **2020/03/09 - HOTFIX**: SCADA Conversion: MervisDB “History saved by PLC” setting. * **2020/02/10 - HOTFIX**: SCADA Export: User schema editing support. * **2020/01/28 - HOTFIX**: SSCP: Username export fix. ===== 2019 ===== * **2019/12/14 - HOTFIX**: SSCP .vlist: Automatic DP type assignment. * **2019/11/22**: AMiT Import: Decimal place constant; SCADA Export: DP timestamp for DB. * **2019/11/13 - HOTFIX**: AMiT/OPC Import: Unit and Conversion columns. * **2019/11/04 - HOTFIX**: AMiT Import: ATouch32 format; SCADA Conversion: Adopted HW.ini parameters. * **2019/10/21 - HOTFIX**: AMiT Import: Header row fix; SCADA Conversion: Graph template ID uniqueness check. * **2019/09/27 - HOTFIX**: OPC Import: Connection check; MervisDbPump key export fix; Extensions: History loading fix. * **2019/09/03 - HOTFIX**: SCADA Conversion: Path validity check; OPC Import expansion. * **2019/08/16 - HOTFIX**: Alarm count limit for monthly history. * **2019/08/09 - HOTFIX**: OPC Import adjustments; Schema: Line object editing fix. * **2019/07/26 - HOTFIX**: OPC variable list DP import. * **2019/06/12**: OPC driver SCADA export support. * **2019/05/15 - HOTFIX**: SSCP .vlist: TPG point updates; SCADA 2 Conversion: MervisDB write enable. * **2019/04/11 - HOTFIX**: SSCP: slaveId setting fix. * **2019/03/29 - HOTFIX**: Bulk functions: Button time setting. * **2019/03/27 - HOTFIX**: SCADA utility update; RVD235: 2-byte analog fix. * **2019/02/25**: SCADA 2 conversion without schemas option. * **2019/01/09 - HOTFIX**: SSCP Import: .vlist filtering performance; AMiT: TPG write fix. ===== 2018 ===== * **2018/12/19 - HOTFIX**: SSCP: Router mode NoResponse handling; SQL dialog save fix. * **2018/11/15 - HOTFIX**: SSCP: TPG exception enable; slaveId bulk fix. * **2018/11/07 - HOTFIX**: SSCP: Driver router mode support; slaveId setting. * **2018/10/31 - HOTFIX**: SCADA Conversion: Freeze fix for schema acceleration. * **2018/10/30 - HOTFIX**: SCADA conversion utility update. * **2018/10/22 - HOTFIX**: SSCP .vlist: TPG type distinction; Schema: Equitherm reference fix. * **2018/09/19 - HOTFIX**: SSCP: Case-insensitive name replacement; SCADA Conversion: Alarm DP core adjustment. * **2018/09/11 - HOTFIX**: SCADA Import: Replace existing DP fix; SCADA Export: “Gone unconfirmed” alarm state; SaiaEx: Station address parameter. * **2018/09/03**: SCADA 2 Import: GUID to RC address generation. * **2018/08/28**: SComm v1.4.1; User access policy cleanup; SaiaEx UDP export. * **2018/08/10**: Max channels set to 400; SCADA Conversion: Automatic schema rotation. * **2018/07/31 - HOTFIX**: SCADA Export: Settings profiles; Port mapping file support; Automatic station conversion in schemas. * **2018/06/20 - HOTFIX**: AMiT: .txt loading and bulk functions; SCADA Export: Energis flag conversion and Access policy export. * **2018/05/29**: AMiT: .ini IP address fix. * **2018/04/23 - HOTFIX**: Sauter EYZ2400: Speed change; SSCP: Real type TPG flag; SCADA Export: Button visibility fix. * **2018/04/10 - HOTFIX**: SCADA Export: XML memory leak fix. ===== 2017 ===== * **2017/12/28**: SSCP .vlist: Filter memory fix. * **2017/12/21 - HOTFIX**: SCADA Export: SoftPLC alarm expansion; Immediate config saving. * **2017/10/11 - HOTFIX**: launch start_ini fix; SSCP: Long variable name display fix. * **2017/09/27 - HOTFIX**: Script alarm evaluation; Schema: Resizing with objects; SCADA Export: Added report. * **2017/08/14 - HOTFIX**: SCADA Export: Duplicate GUID fix; Scripting: GetParticularData string fix; Schema GUID check. * **2017/08/03 - HOTFIX**: XML Export: Decimal separator fixes (.ini and graph templates). * **2017/07/27 - HOTFIX**: SSCP: tpgVersion; SCADA Export: “Force project start”; Input scrollbar fix. * **2017/06/19**: AMiT Import/Export to SCADA support. * **2017/05/09 - HOTFIX**: Saia XML export; Graph Template: Renaming creates new GUID. * **2017/04/14 - HOTFIX**: Modbus: Double int no-rotate; History: RT variable mask fixes. * **2017/04/04 - HOTFIX**: Bulk functions: Button script setting; SCADA 2 Conversion: Schema mapping file and TPG animation fix. * **2017/02/14 - HOTFIX**: Graph CSV: Row/Column swap; SSCP: Server frame length fix; Channel profile loading fix. * **2017/01/18 - HOTFIX**: SCADA 2 Export: Dialog move; Visibility group loading; Zero-size schema loading fix. ===== 2016 ===== * **2016/12/27**: Energis export adjustments; SCADA Conversion: Graph ID retention. * **2016/12/15 - HOTFIX**: SoftPLC Link: Connection on initialization. * **2016/12/12 - HOTFIX**: SCADA Conversion: TCP timeout fix. * **2016/12/09 - HOTFIX**: SCADA project import support. * **2016/10/26 - HOTFIX**: Schema: Object ID uniqueness; SoftPLC Import: GUID and DB name fix; SSCP: CommUID zeroing. * **2016/09/20 - HOTFIX**: Schemas: Multi-station graph jump; Text editor via value display menu. * **2016/09/05 - HOTFIX**: Schemas: Value display initialization fix; Stricter communication error_penalty. * **2016/08/12 - HOTFIX**: XML Export: RC-RC communication fix. * **2016/08/03 - HOTFIX**: Saia: TPG evaluation; Non-update time observation for non-responding points. * **2016/07/22 - HOTFIX**: Communication cycle direction change; Max non-update time setting. * **2016/07/08 - HOTFIX**: Schema: Generic object animation sequence support. * **2016/06/21 - HOTFIX**: Import filter expansion (IDE1/2); Schema: Background Saturation property. * **2016/04/21 - HOTFIX**: SoftPLC Import: Name separator setting. * **2016/04/06 - HOTFIX**: SSCP Import: ACK/RST alarm assignment; historyId display. * **2016/04/04 - HOTFIX**: SSCP: Multi-packet TCP response parsing; TPG write fix. * **2016/03/24 - HOTFIX**: RcWareDB: Data loading adjustment; AMiT to SSCP conversion support. * **2016/02/10 - HOTFIX**: SCADA 2 Conversion: Station-by-station option; Out-of-range history date handling. ===== 2015 ===== * 2015/12/30 - Saving group and tech. unit list for SCADA 2 export. * 2015/12/28 - Fix for SSCP variable name export. * **2015/12/16 - HOTFIX** * 2015/12/16 - SSCP: TPG exception addresses are set during update from .vlist file. * **2015/12/10 - HOTFIX** * 2015/12/10 - Changed saving of station domains after startup to .inw. * **2015/11/30 - HOTFIX** * 2015/11/30 - SSCP Import: Output TPG variable is saved to 13th interface. * 2015/11/24 - Sscp driver fix: proper initialization of SscpClient - bufferSize for communication is set to 2048 bytes. * **2015/11/06 - HOTFIX** * 2015/11/06 - Import from .vlist: Fix for import type setting and data point name generation. * **2015/10/16 - HOTFIX** * 2015/10/16 - Fix for passing MervisDb and RcLink parameters to SCADA converter. * 2015/10/15 - SSCP - Read multiple variables support. * 2015/10/09 - Fix for loading vlist files. * **2015/10/08 - HOTFIX** * 2015/10/08 - Accelerated loading of .vlist files. * **2015/09/04 - HOTFIX** * 2015/08/27 - Export to SCADA 2: Added MervisDb and RcLink parameters. * **2015/08/12 - HOTFIX** * 2015/08/12 - Added Energis definition export for SCADA. * 2015/08/11 - GetParticularData scripting & RcWareDb functions timeStamp fixed. * 2015/08/05 - Saia and Simatic export (for SCADA 2). * **2015/08/04 - HOTFIX** * 2015/08/04 - SSCP: Update from .vlist compares variable names case-insensitively. * 2015/07/23 - User policy not applied when creating a new schema. * 2015/07/23 - Graph template GUID exported to SCADA 2. * **2015/07/14 - HOTFIX** * 2015/07/14 - Export to SCADA 2: GetFormattedValue() returns correctly formatted large numbers. * **2015/07/03 - HOTFIX** * 2015/07/02 - SSCP: Parameter editing - correct variable highlighted in tree. * 2015/07/02 - Export to SCADA 2: Added setting “Use MervisDB driver for communication”. * 2015/07/02 - Adjustment of parameter generation for DbPump. * 2015/06/25 - Fix for loading background image adjustments in schema if transparent. * 2015/06/22 - SSCP Import: Added automatic assignment of ACK and RST variables from alarm block for “SEL” type. * **2015/06/19 - HOTFIX** * 2015/06/19 - Button alignment in computer resource settings dialog. * 2015/06/19 - Added foundation for DbPump definition export. * 2015/06/19 - Export to SCADA 2: Added export of data point occurrences in schemas. * 2015/06/18 - Sscp client: Sscp device constructor for md5 password format. * **2015/06/09 - HOTFIX** * 2015/06/09 - Bulk functions: Added alarm server mirror setting. * **2015/06/03 - HOTFIX** * 2015/06/03 - Conversion to SCADA 2: Added button style, option to convert to TimeSpan data point. * 2015/06/03 - Fix in input dialog if limits have no decimal places. * 2015/05/28 - Export to SCADA 2: SoftPLC Link: Export variable names: Handling invalid XML characters. * **2015/05/25 - HOTFIX** * 2015/05/25 - Export to SCADA 2: Fix for saving all decimal places for analog interface. * **2015/05/21 - HOTFIX** * 2015/05/21 - Export to SCADA 2: Preserving special characters even under Win8. * 2015/05/20 - Export of analog interface value respects decimal places. * 2015/05/14 - Added SSCP parameter export to file for data pump. * **2015/05/13 - HOTFIX** * 2015/05/13 - Adjustment of reading history from files. * **2015/05/11 - HOTFIX** * 2015/05/07 - Export to SCADA 2: Added option to preserve tabs in strings. * **2015/05/06 - HOTFIX** * 2015/05/06 - SSCP: Fix reading variable name from vlist - adding unit to name. * 2015/05/06 - DP Tree Filling: Added empty units and groups. * 2015/04/27 - SSCP: Getting and saving address of associated exceptions variable for TPG value. * 2015/04/27 - Import for SoftPLC Link: Handling max states from state mapping file. * **2015/04/23 - HOTFIX** * 2015/04/23 - Fix for processor load by definition module without connected data points. * 2015/04/22 - SSCP: Adjustments for new .vlist file format. * **2015/04/13 - HOTFIX** * 2015/04/10 - AMiT: Fix for reading TPG. * 2015/04/08 - Fix crash on RC-RC connection with non-existent network channel. * **2015/03/26 - HOTFIX** * 2015/03/25 - Export to SCADA 2: Added option to create rights. * **2015/03/17 - HOTFIX** * 2015/03/17 - Import from splcproj: Added option to use state mapping file (BACnet). * **2015/02/23 - HOTFIX** * 2015/02/23 - SSCP Bulk functions: Added system time setting. * 2015/02/20 - SSCP: AssignDevice() - bool parameter for force create new endpoint (creation doesn't depend on device IP/port uniqueness among devices). * 2015/02/18 - Export to SCADA 2: Added parameters useForceRefreshSetting and commErrorDelay. * 2015/02/12 - English.lng updated. * 2015/02/09 - Schema: Animation export for SCADA - fix for potentially incorrect data point description. * 2015/01/24 - Export to SCADA: Fix for passing “read-only file history” parameter. * **2015/01/23 - HOTFIX** * 2015/01/21 - Added GUID to graph templates. * 2015/01/21 - Export to SCADA 2: Adjusted dialog, added “read-only text history”, adjusted export of animation frames in schemas. ===== 2014 ===== * **2014/12/19 - HOTFIX** * 2014/12/18 - SSCP: Fix value length for direct variable/group reading. * **2014/12/17 - HOTFIX** * 2014/12/17 - Bulk functions: Option to set interface address to parent data point. * 2014/12/17 - Adjustment of line conversion to SCADA 2. * 2014/12/17 - Fix for equitherm conversion to SCADA 2. * **2014/11/24 - HOTFIX** * 2014/11/21 - Export for SCADA 2: dateTimeKind is set to UTC for diagnostic variables in V2 driver model. * **2014/11/19 - HOTFIX** * 2014/11/19 - Export for SCADA 2: New converter version. * **2014/11/14 - HOTFIX** * 2014/11/11 - Equitherm: Fix getting address of connected data point. * **2014/11/07 - HOTFIX** * 2014/11/07 - Export to SCADA 2: Schema: Equitherm link area: Equitherm saves under parent object during export; Animation: Exporting references to individual data point interfaces (usable in scripts). * **2014/11/03 - HOTFIX** * 2014/11/03 - Export for SCADA: Added new settings: File history path, do not set SQL history for points with hysteresis history only, conversion of selected stations. * 2014/11/03 - Schema: Added function “Generate new GUID for all schemas”. * 2014/11/03 - Editor: Added function “Generate new station GUID”. * 2014/11/03 - Equitherm: Export for SCADA - Added min and max heating temperatures. * **2014/10/06 - HOTFIX** * 2014/10/06 - Schemas: Fix loading animation from .sch.inw file. * 2014/10/03 - Export for SCADA: Fixed black text color for link area. * 2014/10/03 - Min and Max in input dialog rounded before use. * **2014/09/21 - HOTFIX** * 2014/09/19 - Adjustments in SCADA 2 conversion; Added export of equitherm in schema. * **2014/09/09 - HOTFIX** * 2014/09/09 - Export for SCADA: Schemas: Added useTransparentColor flag, bitmaps correctly copied before export. * **2014/09/03 - HOTFIX** * 2014/09/03 - RcLink: Added export of DriverDllId and MaxTpgItemsInDay. * 2014/09/03 - RcLink: FlushBuffer() omitted for RcLink TCP connection, using of compression fixed - compression flag is correctly parsed from ESTABLISH telegram. * 2014/08/28 - Fix rendering min and max for equitherm. * **2014/08/27 - HOTFIX** * 2014/08/27 - Fix display of min and max temperature for equitherm. * 2014/08/27 - RcWareDB connection: Added option for HTTP proxy credentials. * **2014/08/22 - HOTFIX** * 2014/08/22 - Exposed extended alarm behavior settings. * 2014/08/05 - SCADA Export: Added export of user policy access rights settings. * **2014/07/31 - HOTFIX** * 2014/07/31 - Schema: Added function “Add marked objects to group”. * 2014/07/17 - SCADA 2 Export: Added RcLink. * 2014/07/14 - SSCP Client: Buffer overflow fix. * **2014/07/03 - HOTFIX** * 2014/07/02 - Script Editing: Allowed saving even with compilation errors. * **2014/06/26 - HOTFIX** * 2014/06/25 - Export for SCADA: Graph in schema: Added fixed Y-axis parameters. * 2014/06/25 - Schemas: Equitherm: Added automatic repainting. * 2014/06/23 - Export for SCADA: Added default period length for history display. * 2014/05/28 - Schemas: Animation object added setting “Propagate button press”. * 2014/05/27 - Export for SCADA: Added parameter “V2 drivers”. * **2014/05/26 - HOTFIX** * 2014/05/26 - SCADA Converter: Added parameter “V2 drivers”. * 2014/05/23 - SCADA Export: Added setting “Confirm button press”. * 2014/05/23 - OPC Client: Added reading/writing Teco TPG structures. * 2014/05/23 - SCADA Export: Fixed export of single station. * 2014/05/23 - SCADA Export: Schemas: “Old” lines converted to new ones before export. * 2014/05/23 - Schemas: Object group not loaded if empty. * 2014/05/23 - Schemas: New connector line uses parameters of last created one. * 2014/05/23 - OPC Client: Float and double distinguished during write. * 2014/05/23 - SSCP Import: Option for automatic DB name creation. * 2014/05/23 - Text Editor: DB name change can be confirmed with Enter key. * 2014/05/23 - SQL Settings: Empty RcWareDbConfig fixed. * 2014/05/12 - SCADA Export: SSCP system time exported with UTC attribute. * 2014/05/05 - Copying DB: Link type interface preserves address if linking to another DB. * 2014/04/30 - Schemas: Animation: Fix station setting. * **2014/04/18 - HOTFIX** * 2014/04/18 - Adjustment of periodic export for intervals smaller than 1 day - bound to whole multiples of period. * 2014/04/17 - dateTimeKind export for SCADA changed. * **2014/04/16 - HOTFIX** * 2014/04/16 - Graphs in RcWeb: Fix “Prefer reading from files”. * 2014/04/16 - Schemas: Link area: Fix station setting. * **2014/04/03 - HOTFIX** * 2014/04/03 - RcWareDB Saving Settings: Added separate saving to XML. * 2014/04/02 - Import data points for SSCP driver from .vlist file: Handling non-existence of last opened file. * **2014/04/01 - HOTFIX** * 2014/04/01 - Added history ID for SSCP. * 2014/03/31 - SCADA Export: SSCP - string DP; NoAct - DP parameter (UpdatePeriod). * 2014/03/10 - SSCP TPG variable type export changed. * 2014/03/05 - Button gadget images copy-to-pictures-dir fix. * 2014/03/05 - image_between_file property added to button gadget. * **2014/02/25 - HOTFIX** * 2014/02/25 - SCADA Converter update. * 2014/02/25 - Modbus RTU fix: Write single coil (ON/OFF state switched). Read single coil as boolean. * **2014/02/13 - HOTFIX** * 2014/02/12 - Added Modbus parameter export to XML for Vision Proxy/SCADA. * **2014/02/12 - HOTFIX** * 2014/02/12 - Fix for alarm processing with memory and saving to alarm history. * **2014/02/05 - HOTFIX** * 2014/02/03 - Check before saving data file: Added check for empty button descriptions. * 2014/02/03 - Added settings for export to SCADA. * 2014/02/03 - Fix searching for equitherm file when generating for RcWeb. * 2014/02/03 - Schemas: When requested station not found, current one is used. * 2014/02/03 - SCADA Export: useSoftPlcValueAttributes is always true. ===== 2013 ===== * 2013/12/12 - Graph in schema: Background color exported for SCADA. * **2013/12/05 - HOTFIX** * 2013/12/05 - Fix for using “Create new GUID for marked DBs” function. * 2013/11/22 - New data point GUID created when copying from clipboard and adding data point. * **2013/11/18 - HOTFIX** * 2013/11/18 - Graph in schemas: showLegend exported to SCADA. * 2013/11/15 - Schema Export: Added GUID check. * 2013/11/15 - Export for SCADA: Added value sorting export for digital points. * 2013/11/14 - SSCP: Changed logger interface; Added proxyid to device configuration; Added variable read via file interface. * **2013/11/08 - HOTFIX** * 2013/11/08 - Added DB definition export to CSV. * 2013/11/07 - Fix setting change in 1/4h max window. * **2013/11/04 - HOTFIX** * 2013/11/04 - Added check for interface linking to itself. * 2013/11/01 - Added SSCP parameter export for SCADA. * **2013/10/23 - HOTFIX** * 2013/10/18 - Added check for unique button names on DP; added check for analog conversion. * 2013/10/18 - Added data file check before export for SCADA. * 2013/10/09 - Schemas: Fix dotted line thicker than 1 pixel; SSCP edit: Remembering last selected variable working. * **2013/10/07 - HOTFIX** * 2013/10/07 - Added max log file size setting for RcWareDb connection. * **2013/09/30 - HOTFIX** * 2013/09/27 - SSCP: Fix direct connection to RT. * 2013/09/27 - SSCP: Added TPG support (Int and Bool only). * 2013/09/25 - Graph template export for SCADA. * **2013/09/24 - HOTFIX** * 2013/09/24 - SSCP: Ability to read histories saved from RT. * 2013/09/19 - Graph template export for SCADA 2. * **2013/09/11 - HOTFIX** * 2013/09/11 - Added ability to change station GUID. * 2013/09/11 - SSCP: Added update from vlist file. * **2013/08/30 - HOTFIX** * 2013/08/30 - SSCP: Added proxy support. * 2013/08/29 - Schemas: Bitmap export for SCADA 2. * **2013/08/26 - HOTFIX** * 2013/08/26 - Schema: Value display/button: Correct station assigned when loading from ini file. * 2013/08/26 - Schema: Fix for missing GIF bitmap in animation. * 2013/08/21 - Station Statistics: Counts number of DPs on individual channels. * **2013/08/20 - HOTFIX** * 2013/08/20 - Schemas: Fix loading data points from another station when viewing via RcWeb. * **2013/08/08 - HOTFIX** * 2013/08/07 - Expansion of SCADA export to include automatic conversion start. * **2013/07/19 - HOTFIX** * 2013/07/17 - Added station and schema export to VisionProxy format file. * **2013/07/12 - HOTFIX** * 2013/07/12 - SSCP: Time sync added. * 2013/07/10 - AMiT: Fix time schedule writing (transferring state from Sunday to Monday). * 2013/07/05 - Schemas: Option to add generic object. * 2013/07/04 - Expansion of export to VisionProxy. * 2013/06/05 - Schemas: Link area: Fix rights check. * **2013/05/24 - HOTFIX** * 2013/05/24 - Written value is logged when writing from script. * 2013/05/23 - Data save check: Added check for links to non-existent data points. * 2013/05/23 - Adjustments to VisionProxy export. * **2013/05/15 - HOTFIX** * 2013/05/15 - SSCP: Fix comm_id (was 16bit instead of 32bit). * 2013/04/19 - MBUS Sensus_FW2: Supply and return temperature fixed. * **2013/04/11 - HOTFIX** * 2013/04/11 - Better handling of automatic station start into communication after RC start. * 2013/04/11 - Extensions: Adjustment of communication with Alarm Server. * 2013/04/10 - Mbus: Added SensusFW2 meter, AEW21 fix. * **2013/03/26 - HOTFIX** * 2013/03/25 - Added HTTP proxy support for RcWareDb connection. * 2013/03/21 - Callback adjustments - SMS sending: If multiple alarms occur at once, SMS is sent for each separately. * 2013/03/15 - SSCP driver: Adjustments. * **2013/03/11 - HOTFIX** * 2013/03/08 - Added overview panel. * **2013/02/18 - HOTFIX** * 2013/02/15 - Added data point import for SSCP protocol. * 2013/02/15 - Fix for history saving thread freeze with very large short-term history file. * **2013/02/13 - HOTFIX** * 2013/02/13 - Script function GetParticularData() expanded with additional parameters. * 2013/02/11 - Station Statistics: Added saving to file. * **2013/02/01 - HOTFIX** * 2013/02/01 - Fix loading graph parameters in schema when viewing via RcWeb. * **2013/01/24 - HOTFIX** * 2012/01/23 - Fixes in station statistics. * **2013/01/17 - HOTFIX** * 2013/01/16 - Alarm export to AS - Option to export only one station. * 2013/01/15 - SSCP: Fix reassigning endpoints. * **2013/01/14 - HOTFIX** * 2013/01/11 - SSCP: Fix return codes. * 2013/01/10 - Added station statistics dialog. ===== 2012 ===== * 2012/12/20 - Export to AS passes URL and credentials. * 2012/12/18 - Editor: Channel number on definition module responds to manual changes. * **2012/12/13 - HOTFIX** * 2012/12/13 - Added communication driver for SSCP protocol. * 2012/12/13 - Added global setting “Do not show SoftPLC Link info window”. * 2012/12/13 - Fix periodic export for longer intervals. * **2012/12/12 - HOTFIX** * 2012/12/10 - Schemas, Image: Fix for periodically loaded bitmap from disk. * **2012/12/05 - HOTFIX** * 2012/12/04 - Schemas: Text object takes user edited text as primary (if enabled). * 2012/12/04 - Paste DB from clipboard without renumbering: Option to preserve GUID. * 2012/12/04 - Added function to generate new GUIDs for marked points. * **2012/11/20 - HOTFIX** * 2012/11/20 - Schemas: User text is not overwritten when loading from .xml. * 2012/11/09 - SoftPLC Link: Variable value is always read regardless of quality (to match state in SoftPLC). * **2012/11/05 - HOTFIX** * 2012/11/04 - Schemas: Alarm and non-update indication settings are saved separately for each station. * 2012/11/04 - Multiple channels can be set to one type at once. * 2012/11/02 - Calling variable extraction from SoftPLC project via UAC when rights are missing. * 2012/11/02 - Bulk change of animation script text. * 2012/11/02 - Added default value settings for RcWareDb connection. * 2012/10/23 - Schemas: Periodic image refresh is correctly initialized. * 2012/10/11 - Schema not saved to .inw when saving undo file. * 2012/10/10 - Schemas: Animation editing - Cannot add tech. unit or group to selected DBs. * 2012/10/10 - Graph: Y-axis minimum and maximum can be entered as decimal numbers. * **2012/10/08 - HOTFIX** * 2012/10/01 - Mutual locking of alarm window and SoftPLC Link info window display. * **2012/09/24 - HOTFIX** * 2012/09/24 - SoftPLC Link: Added setting “Overwrite quality on connection loss”. * **2012/09/03 - HOTFIX** * 2012/08/30 - Added script function GetRcWareDbStatus(). * 2012/08/22 - Schemas: When saving/loading animation to .XML, XML part of inserted objects is also saved/loaded. * **2012/08/02 - HOTFIX** * 2012/08/02 - Added saving schemas to .ini file. * 2012/08/02 - Added function “Save all schemas”. * **2012/07/27 - HOTFIX** * 2012/07/26 - Data point GUID preserved when pasting without renumbering. * 2012/07/26 - Graph print preview adjustments. * 2012/07/26 - Alarm Overview: Added filtering. * **2012/07/16 - HOTFIX** * 2012/07/13 - SoftPLC Link: Fix DateTime write - time zone shift. * 2012/07/11 - Fix missing digital waveform state when exporting graph to CSV. * **2012/07/10 - HOTFIX** * 2012/07/09 - Schemas: Image object added property “Periodically reload from disk”. * **2012/06/27 - HOTFIX** * 2012/06/26 - RcWeb: Fix rights for issuing commands on data point groups. * 2012/06/26 - SoftPLC Link Import: Added function “Replace GUID by table”. * **2012/06/25 - HOTFIX** * 2012/06/24 - BACnet: Further communication changes. * **2012/06/15 - HOTFIX** * 2012/06/14 - Graph: Added value output to text. * 2012/06/11 - BACnet: Changed telegram receive routine. * **2012/06/06 - HOTFIX** * 2012/06/05 - Fix loading history from text files - determining time bounds. * 2012/06/05 - Added support for reading history saved from SoftPLC RT to external graphs. * **2012/05/17 - HOTFIX** * 2012/05/17 - Fix loading schemas from .sch.xml files when displaying for RcWeb. * **2012/05/09 - HOTFIX** * 2012/04/26 - SoftPLC Link: Added reading string into byte array. * **2012/04/02 - HOTFIX** * 2012/04/02 - Script function GetParticularData() is not called if RcWareDb connection is not active. * 2012/04/02 - RcWeb: Button control can be disabled for individual users. * 2012/04/02 - Script function RCRunInternalFunction does not open new schema window if already open. * **2012/03/14 - HOTFIX** * 2012/03/13 - SoftPLC Link: Fix variable linking by RC address. * 2012/03/13 - When processing read TPG value, active mask is set. * 2012/03/13 - Connection: Max connection time applied also for RC-RC connections. * 2012/03/13 - Added setting “Hang up after connection error”. * 2012/03/02 - Graph: Added legend font setting. * 2012/03/02 - AlarmServer connection: String deallocation fix. * 2012/02/24 - Definition module without data points on channel does not block port usage flag. * 2012/02/21 - Graph: Fixed Y-axis max and min can be more than 32268. * 2012/02/15 - Disabled transferring priority update flag to communication library when opening schema. * 2012/02/13 - Added setting “Prefer files when reading history for RcWeb”. * 2012/02/13 - Priority update flag not transferred to communication DLL when opening schemas. * **2012/02/09 - HOTFIX** * 2012/02/08 - Sending priority to communication DLL when reading after write. * 2012/02/08 - Schemas: Files with lowercase extension were not opening. * 2012/02/08 - Reading data saved by RT to RcWareDB: Digital inputs/outputs supplemented with don't care masks. * 2012/02/03 - Memory mapping used for loading file history. * 2012/02/03 - Link area can be used to display in RcWeb. * 2012/02/03 - Graph print preview generates to scaled bitmap. * 2012/02/03 - Option to disable logging writes from script. * **2012/01/25 - HOTFIX** * 2012/01/20 - Saia SComm: Handling max number of read addresses for inputs and outputs. * 2012/01/18 - New API for communication with Alarm Server. * 2012/01/11 - Added GFR parameter export for SoftPLC. * **2012/01/03 - HOTFIX** * 2012/01/02 - Alarm Overview: Current alarms included in print and CSV export. ===== 2011 ===== * **2011/12/19 - HOTFIX** * 2011/12/19 - Alarm confirmation log entry expanded with “command” flag. * **2011/12/13** - SoftPLC Link: Priority update flag transmitted to SoftPLC. * **2011/12/07 - HOTFIX** * 2011/12/07 - RcWeb: Fix loading historical data into graph in schema. * **2011/12/01** - Schemas: Fix automatic image rotation start after opening station window. * **2011/11/25** - Scripting: Expanded RaiseAlarm() function. * **2011/11/23 - HOTFIX** * 2011/11/23 - AMiT: Adjustment of TPG writing. * **2011/11/14** - Adjustments in print and print preview for graphs. * 2011/11/14 - Default number of days for graph display changed from 31 to 7. * **2011/11/09** - RcWareDb server connection checked every 5 minutes even if not saving. * **2011/11/08** - Fix saving grid size settings in TPG editor. * **2011/10/05 - HOTFIX** * 2011/09/30 - Fix loading digital output histories from SoftPLC RT. * 2011/09/30 - Export SoftPLC RT history definition for data pump. * **2011/09/26 - HOTFIX** * 2011/09/22 - Change in communication with Alarm Server. * 2011/09/21 - RcWeb: Added direct link option. * **2011/09/16 - HOTFIX** * 2011/09/07 - Schemas: Edit dialogs were shrinking on dual monitors. * 2011/09/07 - When saving long-term history to RcWareDb, all values assigned same time. * **2011/09/02 - HOTFIX** * 2011/09/02 - M-Bus: Expanded meter type export. * 2011/08/30 - Schemas: Animation edit dialog can resize and preserves size on multiple monitors. * **2011/08/30 - HOTFIX** * 2011/08/30 - Added script functions GetConnectionStatus and IsStationOnLine. * 2011/08/29 - Added function “Send all to VisionProxy”. * 2011/08/29 - Schemas in RcWeb list sorted alphabetically. * **2011/08/23 - HOTFIX** * 2011/08/22 - Init dialog for text entry was displaying twice. * 2011/08/22 - Expanded export to VisionProxy. * **2011/08/16 - HOTFIX** * 2011/08/16 - OPC Client: Correct setting of item types during write. * 2011/08/16 - Added function “Start stations defined on startup”. * **2011/08/08 - HOTFIX** * 2011/08/08 - SoftPLC Link: Another option for automatic DB linking. * **2011/08/04 - HOTFIX** * 2011/08/04 - Fix translation of graph generated for RcWeb. * 2011/08/03 - SoftPLC Link: Added function “Convert from PLC (by RC address)”. * 2011/08/03 - Fix value display editor. * **2011/07/27 - HOTFIX** * 2011/07/26 - Fix periodic export to CSV. * **2011/07/21 - HOTFIX** * 2011/07/21 - TPG: Fixed maximum number of functions. * **2011/07/12 - HOTFIX** * 2011/07/12 - Fix in alarm state mirroring mode from AlarmServer. * 2011/06/17 - Added new script functions (GetDataPointGuid and WriteToLog). * 2011/06/13 - Failed login attempt recorded in log. * 2011/06/13 - Export/Import for SoftPLC: Option to append RC address to variable name end. * 2011/06/09 - Changes in VisionProxy export; option for periodic data sending. * 2011/05/31 - Added function “Stop all communications”. * **2011/05/19 - HOTFIX** * 2011/05/18 - Scripting: Added function GetParticularDataSimple(…). * 2011/05/09 - Users can save graph templates. * **2011/04/21 - HOTFIX** * 2011/04/20 - Support for HTTPS connection to RcWareDb. * 2011/04/20 - Schemas: Added function “Change station for object”. * 2011/04/05 - Script function GetParticularData() expanded with two parameters. * 2011/03/28 - SoftPLC Link: Refresh rate can be more than 32768ms. * 2011/03/28 - Added bulk function “Change script text”. * 2011/03/28 - AMiT: Fix TPG reading. * 2011/03/10 - RcWeb: clearer error message when schema/graph fails to display. * 2011/03/08 - SoftPLC Link: Added info dialog showing connection status at communication start. * 2011/03/07 - Schemas: Added option to open schemas only upon display. * 2011/03/07 - Schemas: Objects can display values from other stations. * 2011/03/03 - SoftPLC Link: Added option to use variable quality as value. * **2011/02/21 - HOTFIX** * 2011/02/21 - Graphs via RcWeb sometimes incorrectly loaded mix of hysteresis and long-term history. * 2011/02/14 - Added INIT value entry via button through RcWeb. * 2011/02/10 - Fix non-functional button control from schemas via popup menu with large number of open windows. * 2011/02/09 - User can change their own password. * 2011/02/08 - Cancelled transferring update time from linked data points. * **2011/01/17 - HOTFIX** * 2011/01/12 - Fix conversion of decimal numbers from SQL in graphs. * 2011/01/10 - Added definition export for import from LTi. * 2011/01/10 - Scripting: Added function GetParticularData(). ===== 2010 ===== * 2010/12/10 - Schemas: Added find & replace string function in text object. * 2010/12/08 - MBus: Added meters PP02, Hydrometer. * 2010/12/08 - Modbus TCP: Adjustments. * **2010/12/06 - HOTFIX** * 2010/12/06 - SoftPLC Link: Fix port range. * **2010/11/04 - HOTFIX** * 2010/11/04 - Added bulk function for string replacement in DB name. * 2010/11/03 - Schemas: Readdressing connected DB expanded with offset option. * **2010/10/15 - HOTFIX** * 2010/10/13 - Adjustment of data point info export format. * **2010/10/05 - HOTFIX** * 2010/10/04 - Schemas: Adjustment of selecting connected data points for value display, button, and time schedule. * 2010/09/28 - RcWare OPC Client: Added wait to synchronous read. * **2010/09/24 - HOTFIX** * 2010/09/24 - Number of communication channels increased to 100. * 2010/09/24 - Option to connect multiple data points to animation object (bypassing letter 'P'). * 2010/09/24 - Pre-selection of marked object for show/hide when editing link area. * 2010/09/21 - SoftPLC Link: Fix reading large numbers (was jamming communication). * **2010/08/18 - HOTFIX** * 2010/08/12 - Schemas: Added setting “Short data point info”. * **2010/06/25 - HOTFIX** * 2010/06/25 - SoftPLC Link: Added “readOnly” flag; Fix crash with long variable names. * 2010/06/18 - Added export option from alarm overview. * **2010/06/07 - HOTFIX** * 2010/06/04 - Fix error when saving from previous version. * 2010/06/03 - Cancelled data saving when opening text editor. * **2010/05/31 - HOTFIX** * 2010/05/31 - External Graph: First version. * 2010/05/25 - Alarm Dialog: “Find DB in text” reflects DB group rights. * 2010/05/25 - Controller Time: Day of week assigned fixed by date (cancelled taking from controller). * 2010/05/24 - Alarm Overview: Further display optimization. * **2010/05/19 - HOTFIX** * 2010/05/19 - SoftPLC Link: Fix loading time for different time zones. * 2010/05/19 - Fix periodic export type “Excel” (only header was written on first save). * **2010/05/14 - HOTFIX** * 2010/05/14 - SoftPLC Link: Limit max values in one query when connecting to MiniPLC. * 2010/05/13 - Added external graph launch. * 2010/05/05 - SoftPLC Link: Only variables with good quality are read; connection to RT not terminated if no variable read. * 2010/05/03 - Link Area: Added property “Optional parameter for link”. * **2010/04/30 - HOTFIX** * 2010/04/22 - SoftPLC Link Import: Marking DP with assigned variable. * **2010/04/22 - HOTFIX** * 2010/04/21 - Alarm Overview: Cancelled regular repainting in simplified view. * 2010/04/21 - Added new dialog for entering analog value. * **2010/04/19 - HOTFIX** * 2010/04/08 - Graph: Added option for fixed Y-axis and its max/min. * 2010/04/06 - SAIA SComm: Reading TPG 7 days zeros rest of table for potential transfer via OPC. * 2010/03/25 - IWKA: Added check for query/response telegram identification. * **2010/03/23 - HOTFIX** * 2010/03/22 - Modbus TCP: Added communication parameters; fixed read function selection error. * 2010/03/19 - Added bulk readdressing function for data points connected to objects in schema. * 2010/03/04 - Adjustments in AlarmServer connection. * 2010/03/03 - Option for user authentication in DomainServer. * **2010/02/15 - HOTFIX** * 2010/02/15 - Modicon Modbus: Adjustments (CRC, byte array). * 2010/02/12 - AMiT: Fix error after TPG write on Ethernet communication. * **2010/02/10 - HOTFIX** * 2010/02/10 - OPC Link: Expanded tree expansion at last visited position. * 2010/02/09 - Saia: Reading TPG 7 days zeros rest of table for potential transfer via OPC. * **2010/02/04 - HOTFIX** * 2010/02/02 - SoftPLC Link: Added function “Convert to OPC connection”. * **2010/01/28 - HOTFIX** * 2010/01/26 - Alarm Overview: Added setting “Simplified overview”. * 2010/01/26 - IWKA: Read fix. * 2010/01/26 - Added “User Login” button to alarm dialog. * 2010/01/26 - Schemas: Added setting “Do not mark objects containing points with update time limits”. * **2010/01/25 - HOTFIX** * 2010/01/21 - Removal of unsupported options in alarm behavior settings. * 2010/01/21 - Schemas: Popup menu on animation sorts data points by group. * 2010/01/18 - Added setting “Do not show message after button press” via RcWeb. * **2010/01/13 - HOTFIX** * 2010/01/13 - Saia: Further adjustments to TPG read/write. * 2010/01/11 - SoftPLC Link: Queries not sent for unknown variables. * **2010/01/06 - HOTFIX** * 2010/01/05 - Saia: Adjustment of midnight transition during TPG write. ===== 2009 ===== * **2009/12/23 - HOTFIX** * 2009/12/23 - Added detection and warning when starting communication on already communicating channel. * 2009/12/23 - SoftPLC Link: Added diagnostic variables. * 2009/12/23 - Increased buffer for spontaneous updates in RC-RC connection. * **2009/12/22 - HOTFIX** * 2009/12/21 - BACnet: Adjustments; Landis: Adjustments. * **2009/12/14 - HOTFIX** * 2009/12/14 - SoftPLC Link: Adjustments to connection detection and login. * **2009/12/09 - HOTFIX** * 2009/12/08 - Fix data point access rights when accessing via RcWeb. * **2009/11/26 - HOTFIX** * 2009/11/26 - Added check for schema name characters unusable in filename. * 2009/11/26 - Graph Export: Correct decimal places fixed. * **2009/11/24 - HOTFIX** * 2009/11/19 - AlarmServer Export: Added additional alarm properties (reaction type). * 2009/11/18 - RcWeb access policy can be used for local operation too. * **2009/11/10 - HOTFIX** * 2009/11/10 - Added user right to toggle fullscreen mode. * 2009/11/10 - AMiT: Revision of TPG read and write. * 2009/11/03 - Added invisible display form to “Button” object. * **2009/10/06 - HOTFIX** * 2009/10/06 - Added option to set post-connection status display. * 2009/09/30 - Saia S-Bus: Adjustment in telegram reading. * 2009/09/15 - Data Export to XML: Added TPG type for SAIA. * **2009/09/01 - HOTFIX** * 2009/09/01 - Fix: Station name can contain space. * **2009/08/25 - HOTFIX** * 2009/08/17 - SoftPLC Link: Fix slow update when connecting to 2 or more RTs. * 2009/07/27 - SoftPLC Link: Added bulk function for string replacement and variable linking. * 2009/07/xx - Added extension for connection to RcWare AlarmServer. * 2009/07/xx - Added extension for connection to EsgDb. * 2009/06/29 - M-Bus: Added further meter definitions. * 2009/06/26 - Schemas: When selecting data point, tree can open at last visited position. * 2009/06/25 - Schemas: Link area can open alarm overview. * 2009/06/23 - Fix error when loading object groups in schema. * 2009/05/29 - Added RcWare connection to Alarm Server. * 2009/05/29 - Added RcWare connection to ESGDB. * 2009/04/08 - Added CSV export to graph pre-print form. * 2009/03/21 - OPC Client: Fix bulk function “replace string in OPC ID”. * **2009/03/13 - HOTFIX** * 2009/03/04 - SoftPLC Link: Added prefix filter when converting from OPC connection. * 2009/03/02 - Fix: Opening data file without data point rights caused program crash. * 2009/03/02 - Fix: TPG editor cannot be opened from schema without appropriate rights. * 2009/03/02 - Added setting “Use last visited directory” when opening bitmaps in schemas. * 2009/02/20 - Electricity: Added new electricity meter. * **2009/02/19 - HOTFIX** * 2009/02/18 - Handling modem order setting. * **2009/02/11 - HOTFIX** * 2009/02/10 - Added function “Save schema to bitmap”. * 2009/01/30 - OPC Client: Added group function “Expand OPC string”. * 2009/01/28 - BACnet: Driver adjustments. * **2009/01/20 - HOTFIX** * 2009/01/20 - ModBus TCP: ByteArray support. * 2009/01/15 - SoftPLC Link: Fix linking non-TPG variable to time schedule type DB. * **2009/01/07 - HOTFIX** * 2009/01/07 - Fix error during alarm check. * 2009/01/06 - Equitherm in schema modified - opens defined template. ===== 2008 ===== * **2008/12/17 - HOTFIX** * 2008/12/17 - SoftPLC Link: Fix TCP timeout setting. * **2008/12/11 - HOTFIX** * 2008/12/09 - Expanded description on running communication tray icon. * 2008/12/01 - M-Bus: Driver adjustments (Actaris Cyble). * 2008/11/27 - SoftPLC Link Import: Added option to create tech. units and groups based on variable name parts. * **2008/11/26 - HOTFIX** * 2008/11/26 - Schemas - Button object: Text color follows setting, not fixed black. * 2008/11/26 - SoftPLC Link: When writing variable, quality [Good, Manual] is sent. * 2008/11/26 - Schemas: When rendering for RcWeb, stretchBackground setting read from .sch.xml file. * 2008/11/24 - AMiT: Communication speed optimization. * **2008/11/19 - HOTFIX** * 2008/11/19 - Modicon ModBus : ByteArray support. * 2008/11/19 - OPC Client: Fix “Forced synchronization in asynchronous mode”. * 2008/11/13 - Value display can show arbitrary data point interface. * **2008/10/20 - HOTFIX** * 2008/10/17 - Added option to close application without confirmation. * 2008/10/16 - SoftPLC Link adjustments: Added conversion from arbitrary driver to SoftPLC Link connection. * **2008/10/15 - HOTFIX** * 2008/10/06 - Fix error when editing button time function. * 2008/09/15 - Adjustments in OPC driver. * **2008/08/08 - HOTFIX** * 2008/08/07 - SoftPLC Link adjustments (Added function for conversion based on variable name; added ignoreQuality parameter). * 2008/08/05 - SoftPLC Link adjustments (Added functions for checking used variables). * **2008/08/04 - HOTFIX** * 2008/07/31 - SoftPLC Link adjustments (Import expansion). * **2008/07/30 - HOTFIX** * 2008/07/29 - Periodic DB export interval settings expansion; periodic Excel export format adjusted. * **2008/07/28 - HOTFIX** * 2008/07/28 - SoftPLC Link adjustments (Import type “SEL”; variable timestamp; added diagnostic variable). * **2008/07/24 - HOTFIX** * 2008/07/23 - SoftPLC Link adjustments (Communication optimization; import dialog expansion). * **2008/07/22 - HOTFIX** * 2008/07/22 - Fix SQL error, removed MySQL support, change in database configuration. * **2008/07/16 - HOTFIX** * 2008/07/14 - M-Bus : DeltaPlus communication fix. * 2008/07/10 - SoftPLC Link adjustments. * **2008/07/08 - HOTFIX** * 2008/07/07 - Time schedule data point output evaluated based on PC time instead of DB update time. * 2008/06/27 - SAIA: Fix 16bit analog write in data mode. * **2008/06/15 - HOTFIX** * 2008/06/10 - Added SoftPLC Link communication library. * 2008/06/06 - Added setting “Show info about unknown SMS”. * **2008/05/15 - HOTFIX** * 2008/05/15 - System activity monitoring: Hangup before connection renewal is now “hardcoded”. * 2008/05/13 - Function “Manage images in schemas” was not working. * 2008/05/13 - Popup menu for schema object missing option to create “Button” object. * 2008/05/12 - Unified max password length for login and user editing. * **2008/04/29 - HOTFIX** * 2008/04/29 - Added continuous saving of port monitor to file. * **2008/04/17 - HOTFIX** * 2008/04/16 - Further adjustments to graph export to Excel. * 2008/04/16 - Added connection name info to “RCCM_BREAK” message. * 2008/04/16 - Fix error when confirming all alarms. * **2008/04/14 - HOTFIX** * 2008/04/11 - Adjustment of graph export to Excel. * 2008/04/10 - Fix TPG display via RcWeb. * 2008/04/10 - Fix calling time schedule editing from schema object popup menu and “Button” object. * **2008/03/28 - HOTFIX** * 2008/03/25 - OPC Link: Added bulk function “replace string in OPC ID”. * 2008/03/24 - Adjustments in VRF Fujitsu driver. * **2008/03/19 - HOTFIX** * 2008/03/16 - Fix TPG editing when adding consecutive events. * 2008/03/14 - Fix confirming non-existent alarm in RC - RC connection. * 2008/03/12 - BACnet: Fix binary value reading; Elink: Fix read telegram processing. * **2008/02/28 - HOTFIX** * 2008/02/26 - HOTFIX [contains error in rwd_opc_link.dll - crashes when editing OPC address] * 2008/02/26 - Added reading multiple values from Schrack meter to M-Bus driver. * 2008/02/25 - Hidden unused settings in “line” object dialog. * 2008/02/25 - Max data points for export from graph to text file increased from 32 to 255. * 2008/02/22 - OPC Link: OPC prefix setting added to bulk functions. * **2008/02/14 - HOTFIX** * 2008/02/01 - Fixes to “system activity monitoring” dialog. * 2008/02/01 - Fix: User without system admin rights could not open SMS overview. * 2008/02/01 - Removed monitoring of “slave” connection loss and subsequent local history saving/loading [unused]. * 2008/01/24 - Number of communication channels expanded to 60. * 2008/01/10 - Link area edit window size set to fixed. * **2008/01/05 - HOTFIX** * 2008/01/03 - Fix function for returning time interval string (connection length). * 2008/01/03 - Expanded columns in communication status bar. * 2008/01/03 - Added option to confirm alarms via SMS only on one station (e.g. “OK ENERGO”). ===== 2007 ===== * 2007/12/19 - Added day of week calculation when transferring controller time between RCs. * 2007/12/19 - Added empty SMS message detection for Siemens MC35 modem. * 2007/12/14 - Added RC address uniqueness check when saving data file. * 2007/12/13 - Enabled button pressing via RcWeb.